share
کابل هیت تریسنگ ریکم  RAYCHEM HEAT TREACING CABLE
  • کابل هیت تریسنگ ریکم  RAYCHEM HEAT TREACING CABLE
  • کابل هیت تریسنگ ریکم  RAYCHEM HEAT TREACING CABLE
  • کابل هیت تریسنگ ریکم  RAYCHEM HEAT TREACING CABLE

کابل هیت تریسنگ ریکم RAYCHEM HEAT TREACING CABLE

کابل هیت تریسنگ ریکم RAYCHEM HEAT TREACING CABLE

اطلاعات تامین کننده

عضو طلایی

الکترو سمکاء samka fixing system

تهران

تولید کننده، وارد کننده، عمده فروش، خدمات

تامین تجهیزات، صنایع، نیروگاهی، نفت، گاز، پتروشیمی، صنایع فولاد، ساختمان ، سیمان

مشاهده سایت فروشنده

مشخصات

کابل
Raychem 3BTV2-CT
کابل
Raychem 5BTV2-CT
کابل
Raychem 10BTV2-CT
کابل
Raychem 8BTV2-CT
کابل
Raychem 20QTVR2-CT
کابل
Raychem 10QTVR2-CT
کابل
Raychem 15QTVR2-CT
کابل
Raychem 20XTV2-CT-T2
کابل
Raychem 15XTV2-CT-T3
کابل
Raychem 8XTV-CT-T3
کابل
Raychem 12XTV2-CT-T3
کابل
Raychem 4XTV2-CT-T3

توضیحات محصول

The XTV family of
Raychem self-regulating heat trace cables provides solutions for industrial
pipe freeze protection and process temperature maintenance applications
requiring high power output. Raychem XTV heat trace cable can withstand
temperatures up to 420°F (215°C) and provide process temperature maintenance to
250°F (121°C). The heating cables are configured for use in nonhazardous and
hazardous (classified) locations, including areas where corrosives may be
present.
The power output
of self regulating electric heat tracing depends on the heating cable
temperature and can provide up to 20 W/ft. at 50°F (10°C). Raychem XTV heat
trace cables meet the requirements of the U.S. National electrical Code and the
Canadian Electrical Code.
Industries
Served:


Chemical and Pharmaceutical
Food and Beverage
Marine
Mining
Oil and Gas
Power
TECHNICALSPECIFICATION 
The heating cable shall
consist of two 14 AWG nickel-plated copper bus wires, separated by a
fluoropolymer spacer and helically wrapped with a self-regulating fluoropolymer
fiber that controls power output so that the cable has an unconditional
temperature identification number (T-rating) of T2C (446°F or 230°C) or lower
without use of thermostats.
 A ground-fault protection device set at 30 mA, with
a nominal 100-ms response time, shall be used to protect each circuit.
 The heating cable shall have a tinned copper braid
with a resistance less than the heating cable bus wire resistance as determined
in a type test (ASTM, B193, Sec. 5). The braid shall be protected from chemical
attack and mechanical abuse by a fluoropolymer outer jacket.
 In order to confirm 3.1B, the self-regulating
heating cable shall retain at least 90 percent of its original power output
after having been cycled 300 times between 50°F (10°C) and 450°F (232°C),
allowing at least six minutes of dwell time at each temperature.
 The heating cable shall have continuous exposure
(maintain) capability up to 250°F (121°C) and intermittent exposure capability
up to 420°F (215°C or 250 psi steam), as manufactured by Tyco Thermal Controls.
For detailed product specifications,
please refer to the product datasheet